208v to 240v transformer. This transformer converts 3-phase 240V Delta to 208Y/120. Pe...

440V Delta primary (input) x 120/240 secondary (outpu

Buck-boost transformers offer an economical solution to the adjustment of line voltages that are slightly above or below normal. When a buck-boost transformer is connected as an autotransformer, only a portion of the load kVA is actually ... 96 100 100 105 110 110 115 115 120 120 200 208 220 220 240 240 115 110 120 115 121 132 126 138 132 144 ...318 products. Control transformers provide voltage regulation and convert high or low voltages to match application needs. In addition, they isolate systems from another. Control transformers are common in electronic circuits that require constant voltage or current with a low power or volt-amp rating. Input Voltage - Transformer. 480V AC.Jun 30, 2021 · A buck-boost transformer with a 7.5:1 winding ratio wired with subtractive polarity can be used to buck the source down to 208V (see Figure 2). The primary is sized for 120 × 240V, while the secondary is sized for 16 × 32V. Figure 2. Voltage can be bucked from 240 V to 208 V to supply a 200 V heater. At 208V, the heater provides 10.8kW of ... You either have a 240V/120V single phase with a center tap or a 240V/120V center tapped 3Ø Delta, the center tapped Delta will have a high leg of around 208V to ground, this is not a usable leg for any 120V loads. Or you have a 208V/120V single phase from a 208V/120V 3Ø. The straight 240V/120V single Ø is what most residencies use.10 kVA Isolation Transformer - 240/208V Primary Voltage - 240V Secondary - Single Phase - NEMA 3RThis transformer is designed to convert 208V 1-Phase power to 120/240v. This unit is great for panels, lighting, CNC machines, and other business machines. ... 240: 208: 417: 75: 361: 313: 625: 100: 481: 417: 833: Shipping. Shipping rates vary, but are generally 10% of the total purchase price.208V to 240V buck boost transformers are a popular option, by being able to buck or boost the operating voltage in small increments, they can extend the lifespan of your electrical equipment, while also protecting said equipment from potential dangers or overloads. 3 Phase Delta Buck/Boost Step-Up Transformer - 208V Primary - 230V Secondary - 20.83 Amps - 50/60HzThis panel jumps into the breakthrough tech innovations that are transforming industries to build a radically better world. How can business, government, philanthropy, and the startup community come together to create a better tomorrow? Hea...Transformers. Siemens Canada offers a full line of one and three-phase, ventilated, dry-type transformers designed to meet the highest industry standards for quality in the commercial, industrial, and OEM markets. Building on years of experience in engineering and design comes a product portfolio that is guaranteed to provide the high ...step-down, then the 240 V primary winding will produce a 120 V. secondary output, but that will be connected hot-to-neutral, and. you will get 208 V line-to-line on the output. You could do this with 3 separate single phase step-down. transformers, but the wiring will get pretty complicated.1-Phase Buck/Boost Step-Down Transformer - 240V Primary - 208V Secondary -35.4 Amps -50/60HzThree Phase Transformer, Input 240VAC Delta. These Three-Phase Transformers offer consistent, smooth voltage transformation at 240VAC input. Transformers 15kVA and higher that meet DOE 2016 legislation will help lower operating costs, lower cost of ownership, increase profitability, and reduce overall greenhouse gas emissions. Temp.10 kVA 240 Volt to 220 Volt Single phase Autotransformer MC10C-C2. NOT in stock. Current lead time to manufacture: 2-3 weeks. Add to Cart. US$ 1,137.00. Catalog No.: MC10C-C2. Autotransformer 10 kVA • Single Phase • Primary: 240 Volt • Secondary: 220 Volt. Conductor: Copper. • Frequency 60 Hz.General Purpose - Multi-Use: Type - General Purpose Transformer; KVA - 5 KVA; Volts, Primary - 240x480V; Volts, Secondary - 120/240V; Phase - 1 Ph; Frequency Rating - 60Hz; Winding - AL Winding; Temperature Rise - 180 deg C; Enclosure Rating - NEMA 3R; Enclosure HxWxD - 17.25x10.00x7.75"; Weight - 96lb 43.54kg; Additional Information - …Three phase transformers are labeled as 120/240V AC primary voltage and 16/32V AC secondary voltage. ... 120V AC, 208V AC, 240V AC, 480V AC: 120V AC, 208V AC, 240V AC: 3,000: 9.9" 9.4" 19.9" UL Listed, CSA Certified: 0000000: 00000000: International AC to AC Transformers . Output for Germany, Spain, and United States.Buck-boost transformers offer an economical solution to the adjustment of line voltages that are slightly above or below normal. When a buck-boost transformer is connected as an autotransformer, only a portion of the load kVA is actually ... 96 100 100 105 110 110 115 115 120 120 200 208 220 220 240 240 115 110 120 115 121 132 126 138 132 144 ...Doing so, you will get a 240 output in the secondary winding. In homes, you may use 240V or 208V in that case knowing how to wire 208V single phase will come in handy. 480V 3-Phase to 240V Single-Phase Transformer Wiring. I am going to show you the wiring diagram for both the options I have mentioned above. Let’s start with the first …3kVA single phase to split phase transformer convert AC220V to 120V/240VAC, the primary voltage can also choose 110V, 208V, 240V, 380V, 415V, 440V and 480V, 50/60Hz frequency, transformer is powerful and reliable, with low cost and high efficiency.Low Voltage Distribution Transformer - Single Phase, 120/208/240/277 - 120/240V, 1.5kVA. Compare. View Details. Resource Quick View. Low Voltage Distribution Transformer - Single Phase, 120/208/240/277 - 120/240V, 10kVA. By Acme Electric . Catalog ID: T279746S.The 20 kVA capacity transformer from ATO is safety and isolation single phase transformer, it can step down 240 volt input voltage to output 208 volt, can step up 208 volt to 240 volt as well. This good price isolation transformer provides enhanced electrical isolation between the line supply and the application. SKU: ATO-T-DG20KVA.The traditional classroom has been around for centuries, but with the rise of digital technology, it’s undergoing a major transformation. Digital learning is revolutionizing the way students learn and interact with their teachers and peers.The ESP Step Down Transformer reduces an incoming 208 Volt wall outlet configuration to 120 Volts. It is a convenient and cost-effective solution to easily adapt your equipment to run on a 208 Volt receptacle without the need for an electrician. Available in two models, it offers the ability to quickly resolve power voltage issues and keep your ... Dry-Type Transformer Division Headquarters Canadian Sales Office Latin American Sales Office JEFFERSON ELECTRIC BEMAG TRANSFORMERS TRANSFELEC INDUSTRIAL SA DE CV 800-892-3755 450-293-8998 +52 (81)1099-5070 [email protected] This is typically what you’ll see in homes and small businesses. 120 volts and 240 volts for a single-phase, and 120, 208, and 240 for three-phase. Depending on how a transformer is wound at the service, you’ll have 208/120 or 240/120, and in the case of a 3phase 4wire Delta application, you’ll have 208/240/120 all in the same service.Single phase transformers are labeled as 120/240V AC primary voltage and 12/24V AC secondary voltage. ... 120V AC, 208V AC, 240V AC, 480V AC: 120V AC, 208V AC, 240V AC: 3,000: 9.9" 9.4" 19.9" UL Listed, CSA Certified: 0000000: 00000000: High-Inrush Panel-Mount AC to AC Transformers .For a 112.5kVA transformer, the primary current would be 112,500VA ÷ (480V × 1.732) = 135A, and for the same transformer, the secondary current would be 112,500VA ÷ (208V × 1.732) = 312A. Step 2 Next, you must protect the primary winding of each transformer against overcurrent, in accordance with the percentages listed in Table 450.3(B) and ...thank you! You are going to end up with 208/120V at the office trailer. Sounds like the only problem will be the AC unit. The AC unit may work with 208V. You could use a buck/boost trasformer to bump the 208v up to 240V. If the AC unit's as old as the trailer spend the money on a new AC unit that is designed for 208V. G.My calculation is as follows (ignoring transformer losses and assuming a balanced load): 480V 3P @200A = 166kVA. 208V 3P @400A = 144kVA. therefore the 200A 480V service has enough power. I consulted with an electrician, and his response was " Not enough power. 208 X 400 =83,200 / 360=231 ".Get the best deals on 45 Kva Transformer when you shop the largest online selection at eBay.com. Free shipping on many ... 45 KVA Hammond NMK045BK 480/277V X 208V 3 Phase Dry Type Transformer N3R Outdoor. or Best Offer. FEDERAL PACIFIC 45 KVA TRANSFORMER - DRY TYPE #307. $600.00 ... ACME TRANSFORMER 45KVA KV PRI 480V 3PH 60HZ T-3-53343-3S 240V ...Shop Amazon for 30 KVA 3-Phase Multi Tap Auto Transformer (600,480,400,240,208V) and find millions of items, delivered faster than ever. ... (3.7Kw) 15 Amp 200-240V 3 Phase Motor, DPS Should Be Used for One Motor Only, Input/Output 200V-240V, Digital Type. 3.7 out of 5 stars ...For the 208V to 240V change, a 1 kVA transformer can reasonably supply 7 kVA of load. But when you have a big voltage change you don't get this benefit. 208V to 480V means that 1kVA of transformer can supply perhaps 1.5kVA of load, not enough benefit to be worth the added complexity in most cases.Buy a wholesale step up transformer 208v to 220v for a convenient running of your electrical power applications. Visit Alibaba.com and order transformers that you like. ... 220v 60hz tv flyback transformer price three phase step up 220v to 440v transformer 12v dc 240v ac ups power 650va transformer $0.30 - $0.40. Min Order: 1 piece. CN Supplier ...Feb 25, 2008. #13. beanland said: If you only need 120/240V single-phase, there is no reason to pay for and install the 3-phase transformer. Connect 480V 2-wire to a 480-120/240V single-phase transformer. Warning: a VFD will generate "50Hz" for a motor but it will be all chopped up and distorted, not a neat sine-wave.Get the best deals on 45 Kva Transformer when you shop the largest online selection at eBay.com. Free shipping on many ... 45 KVA Hammond NMK045BK 480/277V X 208V 3 Phase Dry Type Transformer N3R Outdoor. or Best Offer. FEDERAL PACIFIC 45 KVA TRANSFORMER - DRY TYPE #307. $600.00 ... ACME TRANSFORMER 45KVA KV PRI 480V 3PH 60HZ T-3-53343-3S 240V ...Transformer, Dry Type, TP-1, 480 x 120/208V, 3PH, 30 kVA, ... 30KVA, 3P, 480V, 240V, Energy Efficient Transformer 30 KVA, 3-Phase, 480 Delta Primary Volts - 240 Delta Secondary Volts with 120 Volt Lighting Tap, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size ...66 products. A buck boost transformer is a single phase transformer designed to increase or decrease the voltage applied to alternating current systems such as electronics and lighting systems. By doing so, a buck boost transformer can help improve performance in a variety of electrical equipment by ensuring optimal voltage.Unity Power Factor design enables full 6000VA / 6000W output capacity when used with hardwire 208/240V input power; Optional L6-30P input cord included (output de-rates to 5600W with 240V input & 4800W with 208V input when the L6-30P cord is used). In double-conversion mode, this UPS system maintains perfect output by continuously converting AC ...The difference between phases is 208V rather than 240V because they are 120 degrees out of phase, not 180. You have 208V single phase between any 2 phases. ... To get 240V you need a transformer. Share. Cite. Follow answered Feb 24 at 16:28. user28910 user28910. 3,904 15 15 silver badges 19 19 bronze badges \$\endgroup\$ 1. 1My situation is a 120/240V single phase service feeding a 208V single phase panel (panel feeds both 120V and 208V loads). The contractor suggested using a buck transformer to step down from 240V to 208V. My concern is the neutral conductor and a 120/208V single phase voltage at the panel.A specific K-Factor rating indicates that a transformer can supply its rated KVA load output to a load with a specified amount of harmonic content. For more detail on K-Factor Transformers refer to Federal Pacific's K-Factor Transformer Application Note. Transformer Basics 150°C Rise 115°C Rise 80°C Rise Average Temperature Rise 115°CBuy frequency converters to change 110v/120v 60Hz to 208v/220V/230V/240V 50Hz by built-in transformer, up to 400Hz, convert fixed Hertz to variable Hz power supply. ... to 220V 50 Hz (e.g. NZ) in one step by built in step up transformer, convert 120V 60Hz to 230V, 240V 50Hz with pure sine wave output for household appliances. 1 kVA Frequency ...A hide away bed is an innovative and versatile piece of furniture that can be used to transform any room in your home. Whether you’re looking for a space-saving solution for a small apartment or a way to maximize the functionality of your h...*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS TRANSFORMERS OR SUBSTATIONS* Transformer Features: The MT-BBT-208V-240V-31.2A buck and boost transformer is a single phase unit with a 7.37 KVA rating and a primary voltage of 208 AC using a maximum of 35.4 amps on the primary side.This 3kVA 3kW SmartOnline® isolation transformer converts your UPS, utility or generator's 208V high-voltage input to 120V low-voltage output. It features 12 NEMA 5-15/20R outlets for connecting equipment with common NEMA 5-15P and NEMA 5-20P plugs. Four resettable 20A circuit breakers protect your 120V equipment against overload conditions. The reason for the high leg is to provide 240V three phase to motors and other three phase loads. If you did not need that, then just putting in 120/240 single phase service would be easier except that POCO will be unhappy about the large single phase load imbalancing their system. A 208Y/120 would give you all the 120V you need for lighting loads, but would not give you 240 for resistive ...3 Phase Auto Transformer 240V to 208V | 208V to 240V Delta-Delta or Wye-Wye 60hz. From: $ 711.55 - $ 2,000.90. Add to cart.1 Phase Buck & Boost Step-Up Transformer - 208V Primary - 240V Secondary at 46.8 Amps - 50/60Hz120v to 240v Step Up Transformer 1000W Power Voltage Converters, No Noise, Suit for Coffee Machines, Rice Cookers and Other Kitchen Appliances ,Using 220V Asia Euro Appliance in US. 47. $9599. FREE delivery Mon, Oct 9. Only 13 left in stock - order soon.A standard 240V delta to 208V wye transformer will do the conversion you are asking for. You might also consider using separate single phase transformers to create 120/240V systems. You could use the 'native' 120/240V from the incoming delta for some of the units, and single phase 120/240V transformers to put load on the other legs of the delta.The 20 kVA capacity transformer from ATO is safety and isolation single phase transformer, it can step down 240 volt input voltage to output 208 volt, can step up 208 volt to 240 volt as well. This good price isolation transformer provides enhanced electrical isolation between the line supply and the application. SKU: ATO-T-DG20KVA.Name: buck boost transformer 208 to 240 wiring diagram - Boost Transformer Wiring Diagram Unique Amazing 208 Vs 240 Wiring Diagram Gallery Electrical Circuit File Type: JPG Source: kmestc.com12-8. Cord Grip, Power-Indicating Light. -40° to 165°. NEMA 4X, NEMA 12, IP69K. 120V AC/208V AC. 0000000. 0000000. Choose from our selection of 208V AC outlets, including over 90 products in a wide range of styles and sizes. In stock and ready to ship.Transformer, Dry Type, TP-1, 480 x 120/208V, 3PH, 30 kVA, ... 30KVA, 3P, 480V, 240V, Energy Efficient Transformer 30 KVA, 3-Phase, 480 Delta Primary Volts - 240 Delta Secondary Volts with 120 Volt Lighting Tap, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size ...208v to 240v transformer. 2kva transformer. acme electric. single phase transformers. 5kva transformer. 277v to 120v transformer. Next page. Product details. ... Item - Transformer: Control Transformer Input Voltage - Transformer: 240VAC,480VAC Output Voltage - Transformer: 120VAC VA Rating ...That is to say we are using a 240v delta to 208v wye transformer to go from 208v to 240v. I have fed the 208wye side as my primary with no neutral- just three ungrounded conductors. Normally I have connected a ufer, or some other GEC to xo and then to case of the transformer, and this is done on the secondary side.When it comes to 1.5 kVA Single Phase Transformers, you can count on Grainger. Supplies and solutions for every industry, plus easy ordering, fast delivery and 24/7 customer support. ... 208V AC; 240V AC; 277V AC; 480V AC; 600V AC; Output Voltage - Transformer. 120V AC; 240V AC; VA Rating - Transformer. 50 VA; 100 VA; 150 VA; 250 VA; 500 VA ...Buy a wholesale 208v to 240v transformer for a convenient running of your electrical power applications. Visit Alibaba.com and order transformers that you like.208V 200A 37.5 250A 250A 208V 225A 50 400A 400A 240V 80A 15 100A 100A 240V 150A 25 250A 250A 240V 200A 37.5 250A 250A 240V 225A 50 400A 400A Three Phase Transformers Primary Voltage Main Breaker kVA Rating Primary Lugs Secondary Lugs 208V 60A 15 100A 100A 208V 100A 30 250A 250A 208V 150A 45 250A 250A 208V 225A 75 400A 400A 208V 400A 150 400A 600A Step-Up Transformer 208 to 240V 3kW. SKU: PWVS3 UPC: 687700868316 . $259.60 USD & Free Shipping. 1 in stock - ships in 1-2 business days. Add to Cart. This transformer is designed to convert 3-phase 208v to 3-phase 240v to run equipment such as panels, motors, CNC machines, welders, conveyor systems, pumps, printing equipment, fabrication tools ...distribution transformers are oil-insulated, self-cooled, available in loop or radial feed, and are dead-front. Both the Shrubline and MaxiShrub transformer versions are manufactured with ratings from10-167 kVA. All of these transformers meet or exceed ANSI ®, IEEE and NEMA standards. The Shrubline transformer is a Type-2 single-phaseFeb 16, 2021 · 208/230v motors also have a harder time starting up, and they may produce a problematic voltage drop more often when connected to 208v. Voltage drop usually isn’t an issue for split-phase 240v systems. However, on 208v, the motors start with a lower voltage. Therefore, the same amount of drop will have a greater effect on the system. When it comes to 15 kVA Three Phase Transformers, you can count on Grainger. Supplies and solutions for every industry, plus easy ordering, fast delivery and 24/7 customer support. ... 208V AC Delta; 240V AC Delta; 480V AC Delta; Output Voltage - Transformer. 120V AC; 120V AC Center Tap; 208V AC Wye; 240V AC Delta; 277V AC; 480V AC Wye; VA ...Catalog No.: SC10J-K. Isolation Transformer 10 kVA • Single Phase • Primary: 600 Volt • Secondary: 120/240 Volt. Conductor: Copper. • Frequency 60 Hz. Full Specification. Optional Features. Single phase Isolation Transformer SC10J-K has primary and secondary windings that are physically separated from each other.Inventory Details. Compare. Universal Mount Transformer. AT140A1042. Honeywell Home. -. $32.47 each. Shop 24V transformers from top brands such as Johnson Controls, White Rodgers, Packard, and more. Order online today with fast shipping and easy returns.This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.1-Phase Buck/Boost Step-Up Transformer - 208V Primary - 240V Secondary - 23.4 Amps - 50/60HzGet the best deals on 480V Transformers when you shop the largest online selection at eBay.com. Free shipping on many items | Browse your favorite brands | affordable prices. ... Cutler Hammer Y48G24T06N 480V Pri 240V Sec Delta/Delta Transformer 3Ph 6kVa. $497.11. Was: $799.99. ... 112.5 KVA 480X120/208V, CU Transformer- T348. Westinghouse EMP ...Transformer Features: The MT-BBT-208V-240V-46.8A buck and boost transformer is a single phase unit with a 11 KVA rating and a primary voltage of 208 AC using a maximum of 53.1 amps on the primary side. This step-up transformer has a secondary voltage of 240 and provides up to 46.8 amps available on the secondary side.Features: ·UL Listed, CSA Certified and UL 3R enclosure, meets or exceeds all listing criteria, including NEMA, ANSI and OSHA standards. ·Flexibile - can be used in single phase and three phase configurations. ·Reduce (buck) or raise (boost) line voltage from 5-20%. ·All copper lead wire terminations. ·Long Life, 80° C rise up to 0.15 kVA ...A 208V 3-phase inverter will be about 40% the power of an otherwise equivalent 480V 3-phase inverter. Case and point, compare SolarEdge's 14.4kW inverter with their 33.3kW unit. Same physical size, same output amps, same input amps & string qty, same housing, same heat sink.Input L/N is 120 VAC. Output L/L = 240 VAC. Output L/Fake Neutral is also 120 VAC. which I verified by driving input with 120v and measuring 137 L/L and 68.5 Line to Fake Neutral. Multiplying these numbers by the 208/120 gets me damn near 240VAC & 120 VAC respectively.Low Voltage Distribution Transformer - Single Phase, 120/208/240/277 - 120/240V, 1.5kVA. Compare. View Details. Resource Quick View. Low Voltage Distribution Transformer - Single Phase, 120/208/240/277 - 120/240V, 10kVA. By Acme Electric . Catalog ID: T279746S.Innovative · #14 · Apr 14, 2010. Romex Butcher said: "220" and "240" are the same thing. "220" is what the unqualified use to describe 240 volt circuits. 208 can only be obtained from a 3-phase wye system. 240 volts can be obtained from either a 120/240 residential system or a 240 volt 3-phase delta system.This is really no different than the case of transformer with a delta output of 240V 3-Phase 3-wire. Probably this transformer is dedicated to a specific machine. Hopefully the machine is only a 2-wire input. ... Most pieces of equipment that are 208v Single Phase are dual voltage 208/240v. If so, I'd be looking hard at a 480/ 120/240v single ...460 V Primary Three Phase Control Transformers. ... x 208 secondary (output). 3 phase, 50hz and 60hz available, dry type open and enclosed (Nema 1 - Rated for indoor use) available. Dry type distribution transformer. ... 120/240 V Secondary. 460V Delta primary (input) x 120/240 secondary (output). 3 phase, 50hz and 60hz available, dry type open ...In homes, you may use 240V or 208V in that case knowing how to wire 208V single phase will come in handy. 480V 3-Phase to 240V Single-Phase Transformer Wiring. I am going to show you the wiring diagram for both the options I have mentioned above. Let's start with the first option where we are going to use a 480V/240V single-phase transformer.3 If I install a step down transformer (240V to 208), where is the best place to buy one, other than E-Bay? ... but how often does a used 208V to 240V transformer show up? Thanks for any help, Tommy . C. CalG Diamond. Joined Dec 30, 2008 Location Vt USA. Apr 18, 2009 #10 Tommy3kVA single phase to split phase transformer convert AC220V to 120V/240VAC, the primary voltage can also choose 110V, 208V, 240V, 380V, 415V, 440V and 480V, 50/60Hz frequency, transformer is powerful and reliable, with low cost and high efficiency.Low Voltage Distribution Transformer - Single Phase, 120/208/240/277 - 120/240V, 10kVAThe SU20KXFMRT4U step-down isolation transformer converts 208V or 240V input from any 60 Hz generator, utility or UPS high-voltage source to 240/120V output. 208V or 240V hardwire input connection and hardwire 240/120V output. Supports 4U rack-mount installation in 4-post racks with included brackets.Choose from our selection of transformers, including over 900 products in a wide range of styles and sizes. In stock and ready to ship. BROWSE CATALOG. Abrading & Polishing; ... 240V AC. Input Voltage. 0. 8-5 V D C. 1 0 0-2 4 0 V A C. 1 0 0-2 7 7 V A C. 1 0 0-3 5 3 V D C. 1 1-1 5 V D C. 1 2-2 4 V D C. 1 8 0-2 4 0 V A C. 1 8-3 6 V D C. 1 8-7 5 V ...15KVA, 3P, 480V, 240V, Energy Efficient Transformer. 15 KVA, 3-Phase, 480 Delta Primary Volts - 240 Delta Secondary Volts with 120 Volt Lighting Tap, NEMA 1, Energy Efficient, Energy Star labeled Transformer, Ventilated, 150 Degree C, Aluminum Windings, 60 Hz operation, Frame Size: FR939. For Outdoors use Weather Shield WS57. DOE …Transformer secondarys that operate at over 50 V [250.20(A) and 250.112(I)] must be bonded to an effective ground-fault current path to ensure that dangerous voltage from ground-faults will not remain [250.2(A)(3)]. In addition, separately derived systems shall be grounded to the earth to stabilize the system voltage to earth during normal ...Choose from our selection of control transformers, including over 90 products in a wide range of styles and sizes. In stock and ready to ship. BROWSE CATALOG. Abrading & Polishing; Building & Grounds; ... 208V AC, 240V AC: 24V AC: 40: 6" 2.8" 3.7" 2 1/2 " UL Recognized Component: 0000000: 00000:T279744S - Acme Electric - Acme Transformer - 5 Kva, Single Phase, 60 Hz , 120/208/240/277 Primary Volts , 120/240 Secondary Volts, Upc 04750310208 (old Catalog Number - T-2-79744-s) Brief content visible, double tap to read full content.Amazon.com. Spend less. Smile more.When it comes to 5 kVA Single Phase Transformers, you can count on Grainger. Supplies and solutions for every industry, plus easy ordering, fast delivery and 24/7 customer support. ... 208V AC; 220 V AC; 220V AC; 240V AC; 277V AC; 380V AC; 400V AC; 416V AC; 440V AC; 480V AC; 600V AC; Output Voltage - Transformer. 110V AC; 120V AC; 220V AC; 240V AC;Control transformers are common in electronic circuits that require constant voltage or current with a low power or volt-amp rating. Clear All. VA Rating - Transformer. 500 VA. Note: Product availability is real-time basis and adjusted continuously. The product will be reserved for you when you complete your order.For high Leg delta supply, the electric power supply company installs three transformers to provide 120V, 208V and 240V (1 & 3 Phase) supply voltage levels based on the end user requirement. The primary side of these three step-down transformers are connected to the 4.5k-7.2kV supply.This transformer is designed to convert 3-phase 480v to 3-phase 240v to run equipment such as panels, motors, CNC machines, welders, conveyor systems, pumps, printing equipment, fabrication tools, cryptocurrency miners, datacenter equipment, and other business machines.. Primary Voltage: 480 Delta Secondary Voltage: 240 Delta / 120 This model comes with a center tap (AKA lighting tap) to run 1 ...The SU6000XFMR2U step-down isolation transformer converts 208V or 240V input from any generator, utility or UPS high-voltage source to 120V low-voltage output. 208V or 240V 30A input connection supported via hardware or included L6-30P input plug. Eight 5-15/20R and four 5-15R output receptacles accommodate 5-15P and 5-20P equipment plugs.. In today’s digital age, technology has become an int10 kVA Isolation Transformer - 240/208V Primary Voltage - 10 kVA Isolation Transformer - 240/208V Primary Voltage - 240V Secondary - Single Phase - NEMA 3R When it comes to 45 kVA Three Phase Transf Crypto Hub Transformers provide a LOW-COST solution to transforming voltages for crypto mines.. Part Number: RPS-CHT-150K Transformer Size: 150kVA Primary: 208V Secondary: 240V/415V Frequency: 60Hz Temp Rise: 150C Taps: @ 456V, 504V Windings: Aluminum Wound NEMA Rating: NEMA 1 (indoor) or NEMA 3R (outdoor) Approvals: UL and CSA Approved DOWNLOAD PRODUCT DATA SHEETThree Phase Transformers, Full Load Amperes (FLC) KVA: 208V: 240V: 480V: 600V: 3: 8.3: 7.2: 3.6: 2.9: 6: 16.6: 14.4: 7.2: 5.8: 9: 25: 21.6: 10.8: 8.6: 15: 41.7: 36.1: ... 45 KVA, 3-Phase, 480 Delta Primary Volts - 240 D...

Continue Reading